Fire Detection

Detecting a fire at the earliest possible stage is critical for life safety, operational continuity, and insurance compliance. At NewData, we design, install, and commission conventional and addressable (intelligent) fire detection systems based on the building scale and risk classification, delivering solutions in full compliance with EN 54 standards and the Regulation on Fire Protection of Buildings.

Installation, Commissioning, and Testing

  • Installation of detectors, call points, modules, sirens/strobes, and emergency voice alarm lines
  • Addressing, zone/partition mappings, and uploading of the cause-and-effect matrix
  • Smoke and heat testing with one-to-one functional verification at device level
  • Live on-site testing of evacuation scenarios (HVAC, doors, elevators)
  • Project handover package: as-built drawings, point lists, and test reports

For a Quick Quotation

Share your floor plans, usage types, and the evacuation/voice alarm scenarios you are targeting; we will provide a same-day draft solution including device layout, cause-and-effect recommendations, and an indicative cost. With NewData, your fire detection system delivers early warning, guides occupants correctly, and operates reliably without interruption.

Which Systems Do We Install?

Addressable (Intelligent) Fire Alarm Systems

  • Precise identification of faults and alarms by exact device address in large and multi-story buildings
  • Loop architecture with unique device IDs and open/short-circuit tolerance
  • Cause-and-effect scenarios: HVAC shutdown, elevator recall/evacuation, and release of magnetic door holders

Conventional Fire Alarm Systems

  • A cost-effective solution for small- to medium-scale facilities
  • Zone-based alarm indication with simple installation and maintenance

Alarm, Notification, and Public Address

  • Siren/strobe devices (audible–visual alerts) with floor-based scenarios
  • Emergency voice alarm / public address (EN 54-16): phased evacuation, multilingual announcements, and message automation

Based on space usage classifications (office, archive, transformer room, IT room), ceiling height, airflow conditions, and aesthetic criteria, we determine the appropriate detection technology and perform coverage and detector density calculations.

  • Fire-rated cabling: halogen-free, flame-retardant, fire-resistant lines (E30/E90 classes)
  • Evacuation and safety: smoke damper shutdown, elevator fire recall, turnstile release, and fire door/corridor pressurization
  • Bi-directional integration with BMS/SCADA and CCTV/DCS/ alarm systems
  • Panel, loop, and device capacity with a growth-ready architecture
  • Backup power (battery) supporting the standby and alarm durations required by applicable standards
  • Supervision against faults, failures, and sabotage (line monitoring, device tamper detection)
  • Installation of detectors, call points, modules, sirens/strobes, and emergency voice alarm lines
  • Addressing, zone/partition mappings, and uploading of the cause-and-effect matrix
  • Smoke and heat testing with one-to-one functional verification at device level
  • Live on-site testing of evacuation scenarios (HVAC, doors, elevators)
  • Project handover package: as-built drawings, point lists, and test reports
  • EN 54 declarations of conformity and device certifications
  • Point lists (device name, address, location) and floor layouts
  • Cause-and-effect matrix and emergency procedures
  • User training: panel operation, fault/fire management, and periodic testing
  • Monthly, quarterly, or customized functional testing schedules
  • Monitoring of detector sensitivity and contamination levels
  • Log analysis, battery and line health checks, and firmware updates
  • 4/8/24-hour response options with spare parts and inventory management
  • Office & Shopping Malls: phased evacuation and multi-zone emergency voice alarm scenarios
  • Industrial & Warehouse: beam/flame detection in high-ceiling spaces with HVAC integration
  • Healthcare & Education: silent alarm zones and aspiration detection for critical rooms
  • Hotels & Residential Areas: fast evacuation designs with a strong focus on guest privacy
  • Data Centers: aspiration detection with early warning and interfaces to gaseous fire suppression systems

Why NewData?

  • Vendor-agnostic engineering: selection of the most suitable panels, detectors, and voice alarm (VA) systems based on project needs
  • End-to-end delivery: site survey → design → installation → commissioning → maintenance under a single responsibility
  • Transparent reporting: test records, as-built documentation, and the cause-and-effect matrix are shared with you
  • Future-ready architecture: scalable design adaptable to capacity growth and regulatory updates

Request a Call Back